Resultado da pesquisa (2)

Termo utilizado na pesquisa Ecodopplercardiografia

#1 - Doppler echocardiography in goats Moxotó

Abstract in English:

This study describes the two-dimensional echocardiographic sections, M-mode cardiac dimensions, and Doppler flow indices in Moxotó goats. A total of 32 Moxotó goats were divided into four equal groups (n = 8) according to body weight class: G1 (5-10 kg), G2 (10-15kg), G3 (15-20kg) and G4 (>20kg). All animals underwent echocardiographic tests, two-dimensional and M-mode, and pulsed (PW), continuous (CW) and color flow (CF) Doppler. The spectral formation of echocardiographic images was satisfactory, although some adjustments were necessary to obtain adequate cuts/sections for goats above 20 kg. One-dimensional echocardiographic parameters (IVSD, IVSS, LVIDd, LVIDs, VPWd, LVPWs) and cardiac function index (EF and FS) showed a positive descriptive correlation with body weight in the categories studied. The septal separation of point E was constant among the weight categories investigated, ranging from 0.1 to 0.41cm. The Em/Am ratio was predominantly “>1”, with Emax> Amax in all weight categories, and not affected by the heart rate among the studied weight classes. The IVRT was also uniform among the studied weight classes. The individual flow rates of the aortic valve were higher than the maximum flow rate of the pulmonary valve. The ejection times of the aortic and pulmonary flows were positively correlated with increasing body weight, something also observed on the VTI of flow spectra, given the direct relationship of this variable with the stroke volume inversely to FC. The acceleration time (AT) of pulmonary blood flow was greater than the aortic flow, and directly related to increasing body weight and inversely with heart rate. Thus, the standardization of Doppler echocardiographic variables in goats, should always consider breed, age and body weight as well as repeatability and reproducibility studies and adoption of individual reference elements for reliable development of normal values.

Abstract in Portuguese:

Objetivou-se com este estudo reportar descrições acerca dos cortes ecocardiográficos no modo bidimensional, das dimensões cardíacas pelo modo unidimensional e dos índices de fluxo Doppler em caprinos da raça Moxotó. Foram utilizados 32 caprinos da raça Moxotó, distribuídos em quatro grupos por categoria de peso corporal, de igual número (n=8), em: G1 (5-10kg), G2 (10-15kg), G3 (15-20kg) e G4 (>20kg). Todos foram submetidos a um registro ecocardiográfico pelos modos bidimensional, modo-M, Doppler pulsado (PW), contínuo (CW) e de fluxo de cores (CF). A formação espectral das imagens ecocardiográficas foi satisfatória, contudo algumas adaptações foram necessárias para obtenção adequada dos cortes nos caprinos acima de 20 kg. Os parâmetros ecocardiográficos em modo unidimensional (IVSd, IVSs, LVIDd, LVIDs, VPWd, LVPWs) e índices de função cardíaco (EF e FS) apresentaram uma correlação descritiva positiva com peso corporal enquadradas nas categorias estudadas. A separação septal do ponto E, mostrou-se constante dentre as categorias de peso investigadas, variando entre 0,1 a 0,41cm em caprinos da raça Moxotó. A relação Em/Am foi predominantemente “ >1” em todos os caprinos estudados, com Emax > Amax em todas as categorias, não sendo sujeito a influência da frequência cardíaca dentre as categorias de peso estudados. O mesmo pode ser aplicado ao TRIV, que se mostrou uniforme dentre os intervalos de peso estudados. As velocidades de fluxo da valva aórtica individuais foram superiores a velocidade máxima do fluxo da valva pulmonar. Os tempos de ejeção dos fluxos aórtico e pulmonar apresentaram correlação positiva descritiva com o aumento do peso corporal. Condição também observada sobre o VTI dos espectros de fluxo, dada a relação direta desta variável com o volume sistólico inversamente à FC. O tempo de aceleração (TA) do fluxo pulmonar foi superior ao fluxo aórtico, sendo este relação direta com aumento do peso corporal por categoria estudada e inversamente à frequência cardíaca. Desta forma, a padronização das variáveis ecodopplercardiográficas na espécie caprina, deve sempre considerar particularidades relacionadas ao padrão racial, faixa etária e peso corporal, bem como estudos de repetibilidade e reprodutibilidade e adoção de elementos individuais referenciais para elaboração confiável de valores de normalidade.


#2 - Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in healthy dogs, 30(7):586-592

Abstract in English:

ABSTRACT.- Petrus L.C., Oliveira V.M.C., Pereira G.G. & Larsson M.H.M.A. 2010. [Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in healthy dogs.] Avaliação dos fluxos das valvas aórtica e pulmonar com ecocardiografia Doppler pulsátil em cães clinicamente sadios. Pesquisa Veterinária Brasileira 30(7):586-592. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Professor Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: lilipetrus@hotmail.com This study evaluated aortic (AO) and pulmonary (Pul) valves flow with pulsed-wave Doppler by qualitative (presence of valvar insufficiency and characteristic of flow profile) and quantitative analysis, and the following echocardiographic parameters were obtained: peak (PV) and mean (MV) velocities, velocity-time integral (VTI), acceleration (AT) and ejection (ET) time. Thirty dogs were studied, and to be considered normal, physical, laboratory, electrocardiographic, echocardiographic (uni and bidimensional mode) exams, thoracic radiography, and measurement of the blood pressure were accomplished, and the following echocardiographic parameters were obtained: AO PV= 1.22±19.38m/s; AO MV= 0.72±0.08m/s; AO VTI= 0.14±0.02m; AO AT= 38.80±11.29ms; AO ET= 197.90±24.77ms; Pul PV= 0.95±0.18m/s; Pul MV= 0.63±0.10m/s; Pul VTI= 0.13±0.02m; Pul AT= 70.97±18.87ms; Pul ET= 203.70±28.98ms. Heart rate presented negative correlation with AO VTI, AO ET, Pul VTI, Pul AT, Pul ET, and the variable weight had positive correlation with AO VTI, AO AT, AO ET, Pul VTI, Pul ET, differently from the gender, that had no influence on the evaluated parameters. The comparison of aortic and pulmonary valves flow demonstrated AO PV and AO MV higher than Pul PV and Pul MV, respectively, AO VTI higher than Pul VTI, and Pul AT higher than AO AT.

Abstract in Portuguese:

RESUMO.- Petrus L.C., Oliveira V.M.C., Pereira G.G. & Larsson M.H.M.A. 2010. [Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in healthy dogs.] Avaliação dos fluxos das valvas aórtica e pulmonar com ecocardiografia Doppler pulsátil em cães clinicamente sadios. Pesquisa Veterinária Brasileira 30(7):586-592. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Professor Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: lilipetrus@hotmail.com Avaliaram-se com Doppler pulsátil os fluxos das valvas aórtica (AO) e pulmonar (Pul) por meio de análise qualitativa (presença de regurgitações valvares e características do espectro avaliado) e quantitativa, com obtenção de parâmetros ecocardiográficos como velocidades máxima (V. Max.) e média (V. Me.), integral de velocidade (VTI), tempo de aceleração (TA) e ejeção (TE), de 30 cães considerados clinicamente sadios por meio de exames físico, laboratoriais, eletrocardiográfico, ecocardiográfico (modos uni e bidimensional), radiográfico de tórax e mensuração da pressão arterial sistêmica. Obtiveram-se os seguintes resultados para os referidos parâmetros: V.max. AO= 1,22±19,38m/s; V. Me. AO= 0,72±0,08m/s; VTI AO= 0,14±0,02m; TA AO= 38,80±11,29ms; TE AO= 197,90±24,77ms; V. Max. Pul= 0,95±0,18m/s; V. Me. Pul= 0,63±0,10m/s; VTI Pul= 0,13±0,02m; TA Pul= 70,97±18,87ms; TE Pul= 203,70± 28,98ms. Em apenas três animais observou-se regurgitação pulmonar. Alguns parâmetros apresentaram correlação negativa com a variável freqüência cardíaca (VTI AO, TE AO, VTI Pul, TA Pul, TE Pul); outros correlação positiva com a variável peso (VTI AO, TA AO, TE AO, VTI Pul, TE Pul,) e não se observou influência da variável sexo na maioria dos parâmetros avaliados. Na comparação entre os dois fluxos, observaram-se V. Max. AO e V. Me. AO maiores que V. Max. Pul. e V. Me. Pul., respectivamente, VTI AO maior que VTI Pul, e TA AO menor que TA Pul.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV