Year 2009 - Volume 29, Number 01


Title
Avaliação in vitro da eficácia de desinfetantes comerciais utilizados no pré e pós-dipping frente amostras de Staphylococcus spp. isoladas de mastite bovina, p.71-75
Authors

Abstract
ABSTRACT.- Medeiros E.S., Santos M.V., Pinheiro Jr J.W., Faria E.B., Wanderley G.G., Teles J.A.A. & Mota R.A. 2009. [In vitro evaluation of the efficacy of commercial disinfectants used in pre and post-dipping against Staphylococcus spp. isolated from bovine mastitis.] Avaliação in vitro da eficácia de desinfetantes comerciais utilizados no pré e pós-dipping frente amostras de Staphylococcus spp. isoladas de mastite bovina. Pesquisa Veterinária Brasileira 29(1):71-75. Departamento de Medicina Veterinária, Universidade Federal Rural de Pernambuco, Rua Dom Manoel de Medeiros s/n, Dois Irmãos, Recife, PE 52171-900, Brazil. E-mail: rinaldo.mota@hotmail.com

The objective of this investigation was to evaluate the in vitro sensibility of Staphylococcus spp. to several commercially available disinfectants used for pre and post dipping. A total of 60 isolates of Staphylococcus spp., identified as Staphylococcus aureus (50) and Positive coagulase Staphylococcus (10) were obtained from the mammary glands of dairy cows with subclinical mastitis in the regions of Metropolitan Recife, the Agreste and the Zona da Mata of the State of Pernambuco, Brazil. As active ingredients were used a chlorine base (25%), iodine (0.6%), chlorhexidine (2.0%), quaternary ammonium (4.0%), and lactic acid (2.0%) at four specific intervals (15", 30", 60", and 300"). One hundred percent of S. aureus was found to be sensitive to iodine, 93.3% to chlorhexidine, 80% to ammonia, 35.6% to lactic acid, and 97.8% were resistant to chlorine at a 60-minute interval. With respect to the Positive coagulase Staphylococcus (SCP), 100.0% of the isolates were sensitive to iodine, 81.8% to quaternary ammonium, 99.9% to lactic acid, 72.7% to chlorhexidine, and 100% was resistant to chlorine at an interval of 60 minutes. It can be concluded that the highest disinfectant activity in vitro was found to be with iodine and chlorhexidine for S. aureus, and with iodine and lactic acid for SCP. A further conclusion was that it is important to undertake a periodic evaluation of the disinfectants used on the dairy properties in the regions studied, given the variety of sensibilities and resistance to disinfectants used, which may prejudice the control of bovine mastitis caused by Staphylococcus spp.
Download / View
  
 
Colégio Brasileiro de Patologia Animal CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico Coordenação de Aperfeiçoamento de Pessoal de Nível Superior ISI Web of Knowledge SciELO - Scientific Electronic Library Online Banco de Dados Bibliográficos da USP UnB - Universidade de Brasília UFRRJ - Universidade Federal Rural do Rio de Janeiro CFMV - Conselho Federal de Medicina Veterinária